Grant OMK610 Paint Oven Profiling System

Everything you need for paint oven temperature profiling and paint  cure calculations in one easy to use and convenient system. Having over  40 years experience in the manufacture of oven recorders for the  coatings industry, Grant has designed the latest OMK610 kits to boast  many new features to assist in production quality control and reducing  operating costs.

• Enhanced thermal barrier giving maximum protection - now available with a heat absorbing insert
• New fast response probes for both air and surface temperature
• PaintView data storage, report generation and analysis included
• Up to 6 temperature channels, storing up to 250,000 readings

Three OMK610 kits are available based on the OQ610 data logger, each  come with PaintView software, thermal barrier, carry case and a quick  start guide. A choice of temperature probes available for the OMK610-NP  and OMK610 HS kits

OMK610-NP
OQ610 logger with thermal barrier allowing operation to 250⁰C for up to 50 minutes - order probes separately

OMK610 HS
OQ610 logger with enhanced thermal barrier allowing operation to 250⁰C for up to 100 minutes - order probes separately

In stock Yes No
Price was € (Inc. VAT) RRP € Price was € (Ex. VAT) RRP €

Benefits of using the OMK610 kits

• Meets paint manufacturers' specified cure parameters
• Maintains a specified level of cure ensuring repeatable quality
• Maximises oven usage and throughput
• Optimises oven running (energy) costs
• Archives data and results as part of any quality control system or supplier audit trail
• Line operators can use it without the need for a PC

Features

• The Squirrel OQ610 can record up to eight readings per second from each sensor and store up to 250,000 readings in its memory
• Small, robust thermal barrier can now accept a stainless steel heat sink, which greatly extends the system performance (TB612)
• At the end of the recording run, data is downloaded directly to PC for analysis and reporting using PaintView software
• Up to 6 K-Type temperature probes can be connected to the logger.  These probes can be clipped on to non-magnetic components or via a  magnet
• Configure the OQ610 logger for all oven applications
• Clear Multilanguage LCD screen indicates cure % at the end of the cycle (English, German, French, Spanish and Italian)
• Create paint cure data libraries (by manufacturer and / or paint type)
• Set optimised cure temperature curves with upper and lower limits
• Create graphical and statistical data reports via the Report Wizard, incorporating company logos and JPEG photographs

             


General purpose temperature logger
Temperature profiling system for paint & finishing ovens

OQ610
OMK610 system
Analogue input channels
6
6
Input types:


- Temperature, K Thermocouple


- Temperature, T Thermocouple


Max number of readings (per second per channel)
8
8
Basic accuracy
0.5°C
0.5°C
Memory size/number of readings stored
0.25Mb
0.25Mb
USB communications


Set-up/analysis software
SquirrelView or SquirrelView Plus*
PaintView
Temperature probes
optional
optional select from 3 types
TB series thermal barrier (for 'through process; monitoring in the food industry)
optional
n/a
TB612 thermal barrier (for use in paint and finishing ovens) 250°C for 100 minutes
optional
Select either TB612 or TB610
TB610 thermal barrier (for use in paint and finishing ovens) 250°C for 50 minutes
optional
Select either TB612 or TB610