Data Station DS-3200 Series Sound and Vibration Real-Time Analysis System

A real-time analysis instrument for sound and vibration data.

The DS-3200 series data station is a PC-based FFT analyser with high functionality and high performance. This new FFT analyser has two times more real-time analysis capability compared to the older DS-2000 series, having high-speed calculation performance, reliability, and user-friendliness, based on our accumulated experience.

Supporting USB 3.0 enables fast data transmission by connecting a commercial cable for USB 3.0. Up to 32 channels of simultaneous recording is available, in audible frequency (20 kHz), with a dynamic range of 110 dB max (40 kHz unit only).

There are two types, the 40 kHz unit and 100 kHz unit. The former excels at the measurement of acoustics and vibration, the latter is ideal for ultrasonic wave and frequency characteristic measurement.

In addition to multi-channel simultaneous measurement with a wideband frequency range, various acoustics and vibration analysis software can be used with the DS-3200 series. The DS-3200 series can be used almost anywhere in any environment, which makes it the perfect instrument to deal with your site's noise and vibration issues.

Features

  •  USB 3.0 interface enables fast data transmission to a PC
  •  Available 2 types of input units, 40 kHz range and 100 kHz range
  •  Fast real-time rate. Available up to 8-channel for 40 kHz range, 2-channel for 100 kHz
  •  High performance of throughput function. Available up to 16-channel for 40 kHz, up to 4-channel for 100 kHz
  •  High dynamic range of 110 dB and arithmetic processor of FFT up to 16384 points
  •  The number of the channels can be increased from 2-channel to 64-channel. (Connecting two 32-channel units using a frame link cable and make it 64-channel.)
  •  B5 size, compact, about 2.2 kg lightweight unit (2-channel/ 4-channel)
  •  Integrates several analysis functions into one software which are FFT analyzer, tracking analyzer, octave analyzer to provide communization of procedure
  •  "Real-time analysis and recording" system: enables automatic backup data recording and real-time analysis at the same time
  •  Unit connecting function "FRAME LINK": Provides flexible building of multi-channel measurement system only by connecting two units of the DS-3000 via a cable and an interface. (Can be increased up to 64-channel.)
  •  Operating software are 32-bit version of Windows® XP, Windows Vista® and Windows® 7.
  DS-0362/0364 (for 40 kHz unit) DS-0366 (for 100 kHz unit)
Number of input channels DS-0362 : 2 ch
DS-0364 : 4 ch
2 ch
Input connector BNC (C02 type)
Input impedance 1 MΩ ±0.5 % 100 pF or less
Input format Single-ended Isolated single-ended
Input coupling DC or AC (-3dB, 0.55 Hz or less)
Isolation - Insulation of each channel (continuous) 
Dielectric strength voltage between inputs and input/output: 50 Vrms
Sensor power current +24 V/4 mA
Cable disconnection detecting function Detects cable disconnection when using CCLD
TEDS (* Note) IEEE1451.4 (Ver. 0.9, Ver.1.0) accelerometer, microphoneIEEE1451.4 (Ver.1.0) power sensor
Sound filter A and C frequency weightings 
IEC 61672-1:2002 Class1
ANSI S1.4-1983 TYPE1 
JIS C1509-1:2005 Class1
Input voltage range -40 to +20 dBVrms (7-range, 10 dB-step)
Absolute maximum input voltage AC 70 Vrms, for one minute (50 Hz) AC 50 Vrms, for one minute (50 Hz)
Residual offset voltage -20 to 20 dBVr range:-60 dB F.S.
-40 to -30 dBVr range:-40 dB F.S.
0 to 20 dBVr range:-60 dB F.S. 
-40 to -10 dBVr range:-45 dB F.S.
Input level monitor Lights up in red LED at excessive input.
Lights up in red for 95 % or more of a range F.S.
Frequency range DC to 40 kHz DC to 100 kHz
A/D convertor 24 bitΔΣ type 16 bit
Dynamic range 110 dB or more (40 kHz range, 0 dBVr range, analysis for 2048 points) 90 dB or more (at -10 to 20 dBVrms range)
70 dB or more (at -40 to -20 dBVrms range)
Amplitude flatness ±0.3 dB or less
Full scale accuracy ±0.1 dB or less (at 1 kHz) ±0.05 dB or less (at 1 kHz)
Amplitude linearity ±0.0015 % (with respect to F.S.) ±0.015 % (with respect to F.S.)
Channel-to-channel Cross-talk -100 dB or less (at 1 kHz)
Channel-to-channel gain accuracy ±0.3 dB or less (in the same range) ±0.05 dB or less (DC to 20 kHz) 
±0.1 dB or less (20 kHz to 100 kHz, in the same range)
Channel-to-channel phase accuracy ±0.4° or less (up to 20 kHz)
±0.8° or less (20 kHz to 40 kHz)
 *Will be separately defined when unit connection by FRAME LINK. when unit connection
±0.3° or less (DC to 20 kHz) 
±0.7° or less (20 kHz to 100 kHz, in the same range)
Digital filter   FFT aliasing filter
· Base-band: 10th order ellipse 
· Zoom: 6th order eclipse  Real-time octave band filter
 · 6 order butterworth : IEC61260-1995 Class1
Monitor output Output as the standardized signal by input voltage range.
When an acoustic filter is used, the output is the signal which passed through the filter.
Monitor output terminal ρE.5 stereo mini jack ρE.5 monaural mini jack (×2)
Monitor output voltage 1 Vrms F.S. ±1.0 % with respect to input range (with 1 MΩ load) 1 Vrms F.S.±1. 0% with respect to input range (with 1 MΩ load, at 1 kHz)
Output impedance Approx. 33 Ω
Outer dimensions 257 mm (W)×28 mm (H)×180 mm (D)
Power supply voltage Rated DC 15 V (10.5 to 16.5 V)
Supplied from a main unit
Operating temperature range 0 to 40 °C (with no condensation)
Storage temperature range 10 to 60 °C (with no condensation)
Weight 0.9 kg or less
CE marking Applicable

* DS-0362 can be used with the DS-0364 in the same system.
* DS-0362/0364 cannot be used with the DS-0366 in the same system.
* DS-0364 can be connected to up to 8 units (32 channels).
* DS-0366 can be connected to up to 2 units (4 channels). 
* Software for DS-3000 series (model name: DS-03xx) can be used for both 40 kHz and 100 kHz units.
* Software for DS-2000A series (model name: DS-02xxA) can be used for only 40 kHz units. (cannot be used for 100 kHz units.)

* Note: If a TEDS supported sensor made by other companies is used, TEDS information may not be read depending on the type of a TEDS tip included in a sensor.

             1. If you are considering the purchase of a TEDS sensor made by other companies, please consult to the manufacturer or dealer of the TEDS sensor,
             and perform the operation check.

             2. When you want to use a TEDS sensor you already have with the TEDS supported measurement instruments made by Ono Sokki, 
             please perform the operation check with a demonstration product of Ono Sokki.
            (Please consult your nearest distributor or Ono Sokki sales office nearby.)

Write a review